WCB 24inch 1500LBS BW big Gate Valve GVC-001500-W

        WCB 24inch 1500LBS BW big Gate Valve GVC-001500-W

        Short Description:

        Series No.: GVC-001500-W

        China WCB super quality Gate Valve Manufacturer DEYE Provides WCB 24inch 1500LBS BW big Gate Valve, API 600,24inches, ?Gearbox Operation, ASME B16.10, ?-29~+425.

        √ 15+ Years’ Experience in Flow control valve

        √ CAD drawings TDS for each Project Inquiry

        √ Test Report includes Photos and Videos for each Shipment

        √ OEM & Customization Capability

        √ 24Months Quality Guarantee

        √ Three Cooperated Foundries to support your fast delivery.


        Feature

        Products Range:

        Performance:

        Application:

        Product Tags

        Quick Detail:WCB 24inch 1500LBS BW big Gate Valve

        Design standard: API 600

        Body material: WCB

        Nominal diameter: 24” 20”

        Pressure: CL1500LBS?

        End connection: Butt Welded ?

        Face to face: ASME B16.10.

        Working temperature: -29~+425.

        Mode of operation: Gearbox.

        Test and inspection: API 598.

        PSB OS& Y Design valve

        Pressure Seal Gate Valve

        Full bore Valve

        Bi-Direction Gate Valve

        ?

        Products Range:

        Available Material: . A216WCB/LCB/WC9/C5/CF8M/CF3/4A/5A

        Optional stem/shaft: A182F6a, SS, F51/F53

        Optional seal/Seat: Trim 5#, Trim 8#, Trim 10# Trim 12#

        Optional End connection: BW END ANSI B16.25

        Flanged ends RTJ ANSI B16.5, B16.47A

        threaded. ANSI B1.20.1

        Optional Operation: Hand wheel, Gearbox, Electric, Pneumatic

        Range of the size diameter: 2″~60″ (DN50~DN1500).

        Range of the Rating: 900lbs~2500lbs (PN16~PN420).

        Customized Design is negotiable.

        ?

        Performance:

        Common faults and solutions

        When water vapor or droplets appear around the valve stem or gland above the packing cavity (cannot be eliminated by tightening the gland bolts and nuts), pay attention to the following points:

        1. If the gland has reached the end of the stroke, replace it with a new Packing graphite.
        2. Packing may have hardened to fill the cavity. Replace with new packing.
        3. Incorrect packing is used, and the temperature and pressure of the packing can’t meet the requirements.
        4. The valve stem may be grooved, worn, scratched or bent. Replace the valve stem and replace it with a new packing.
        5. The packing rings of each segment cannot be evenly surrounded around the valve stem.
        6. ?The packing gland may be stuck with the packing cavity or valve stem. If the packing is not pressed properly, make sure that the gland is buckled into the packing cavity and pressed down evenly.

        ?

        Application:

        Anti-leakage self-sealing gate valve is widely used in coal chemical, petrochemical, rubber, paper, pharmaceutical and other pipelines as a medium for confluence or flow direction switching device

        ?


      1. Previous:
      2. Next:

      3. Available Material: . A216WCB/LCB/WC9/C5/CF8M/CF3/4A/5A

        Optional stem/shaft: A182F6a, SS, F51/F53

        Optional seal/Seat: Trim 5#, Trim 8#, Trim 10# Trim 12#

        Optional End connection: BW END ANSI B16.25

        Flanged ends RTJ ANSI B16.5, B16.47A

        threaded. ANSI B1.20.1

        Optional Operation: Hand wheel, Gearbox, Electric, Pneumatic

        Range of the size diameter: 2″~60″ (DN50~DN1500).

        Range of the Rating: 900lbs~2500lbs (PN16~PN420).

        Customized Design is negotiable.

        ?

        Common faults and solutions

        When water vapor or droplets appear around the valve stem or gland above the packing cavity (cannot be eliminated by tightening the gland bolts and nuts), pay attention to the following points:

        1. If the gland has reached the end of the stroke, replace it with a new Packing graphite.
        2. Packing may have hardened to fill the cavity. Replace with new packing.
        3. Incorrect packing is used, and the temperature and pressure of the packing can’t meet the requirements.
        4. The valve stem may be grooved, worn, scratched or bent. Replace the valve stem and replace it with a new packing.
        5. The packing rings of each segment cannot be evenly surrounded around the valve stem.
        6. ?The packing gland may be stuck with the packing cavity or valve stem. If the packing is not pressed properly, make sure that the gland is buckled into the packing cavity and pressed down evenly.

        Anti-leakage self-sealing gate valve is widely used in coal chemical, petrochemical, rubber, paper, pharmaceutical and other pipelines as a medium for confluence or flow direction switching device